PowerTector Battery Guard

POWERTECTOR

LOW VOLTAGE DISCONNECT

SOLID STATE BATTERY GUARDS

The PowerTector Battery Guard is a solid state battery device that will monitor the source voltage and disconnect the equipment from the battery if the voltage falls below a pre-determined level. This can work to ensure that there is always sufficient voltage remaining in the battery to start a vehicle engine or ensure power is available for other critical applications. The total discharge of a lead acid battery can also cause damage to the cells significantly shortening the life of the battery. The PowerTector unit can also be set to disconnect equipment at a lower voltage that will still protect the battery from total discharge, while allowing for maximum battery usage. A timed version is also available which will disconnect automatically a set period after the ignition has been switched off.

PT40 - Yellow.png
A WIDE RANGE OF FEATURES

There are six units in the range from 20A to 200A. The 20A unit offer a simple inline system, usually wired to a specific piece of equipment.

These units do not require chassis mounting and simply connect and tie wrap neatly within the wiring system. 

The 40A and 60A units are connected by M6 brass bolts, the 100A and 200A by M10 brass bolts and use a three point mounting system to avoid rocking or stress to the electronics when mounted on uneven surfaces. Heat is dissipated into our custom manufactured die cast casing and all units will operate at full power without additional heatsink 

dissipation.

MANUAL SHUTDOWN FACILITY

From 40A upwards, the units have the facility to be manually shutdown either through the ignition or a dedicated switch. In addition, from 100A upwards 

the units can have an override switch fitted. This allows the units to be reactivated for four minutes to allow emergency actions to be performed.

ALARM & DISCONNECT DELAY FEATURE

An alarm output is supplied which, once the threshold has been reached for 10 seconds, will activate, sounding an alarm or other indicating device for a further 50 seconds prior to 

disconnection. This allows the operator to restart the engine or take other action to maintain continuous power.

TIMED VERSIONS

In addition to the standard PowerTectors, the PT-T versions offer a timed facility. This will disconnect the output after a set time after the ignition has been turned off. If required, during this time period, the voltage can still be monitored and disconnected if it falls below a set level to protect the battery power and system. The unit will 

reactivate when the ignition has been turned on again and the battery voltage has reached 8.5Vdc (12V systems), 17Vdc (24V systems).

FULLY PROGRAMMABLE

All units in the range are supplied pre-programmed for a variety of scenarios offering higher or lower 

disconnect voltages and it is quick and simple to select the correct programme to suit your needs.

PT20 - Yellow.jpg
PT60 - Yellow.png
PT200 - Yellow.png

CHOOSE YOUR POWERTECTOR PRODUCT

TECHNICAL DATA

Our offices

Alfatronix Limited UK

Manufacturing 

Sales Enquiries 

Tel: +44 (01202) 715517

Email: sales@alfatronix.com

Web: www.alfatronix.com

Address:

29 Newtown Business Park

Poole, Dorset, England, BH12 3LL

Alfatronix - France

Demandes Commerciales

Eric Noel:

Mob: +33 (0)682 917410

Email: enoel@alfatronix.com

Web: www.alfatronix.com

bottom of page